Intracardiac echocardiography-guided transseptal puncture in anteroinferior native septum site for patients undergoing atrial fibrillation ablation with atrial septal closure devices: A case series
This case series describes the safety and feasibility of an anteroinferior transseptal puncture (TSP) in patients implanted with atrial septal defect (ASD) closure devices for atrial fibrillation (AF) ablation. Eight AF ablation procedures were performed in seven patients (58.4 ± 8.7 years; two males) with symptomatic AF and percutaneous ASD closure. Typically, the TSP site for patients with an ASD closure device is located in the inferior-posterior region of the native septum. However, with larger devices (>26 mm), limited space in this area can pose challenges for transseptal access. Using transthoracic echocardiography and 3D cardiac computed tomography, TSP sites were pre-determined, targeting the anteroinferior native septum. Closure device diameters averaged 23.8 ± 10.8 mm (range: 10 – 40 mm), with five cases involving devices ≥26 mm. The procedures were guided by fluoroscopy and intracardiac echocardiography, achieving a 100% success rate without TSP-related complications. These findings suggest the anteroinferior TSP approach is a safe and viable alternative for patients with large ASD closure devices.
- Spies C, Khandelwal A, Timmermanns I, Schräder R. Incidence of atrial fibrillation following transcatheter closure of atrial septal defects in adults. Am J Cardiol. 2008;102(7):902-906. doi: 10.1016/j.amjcard.2008.05.045
- Santangeli P, Di Biase L, Burkhardt JD, et al. Transseptal access and atrial fibrillation ablation guided by intracardiac echocardiography in patients with atrial septal closure devices. Heart Rhythm. 2011;8(11):1669-1675. doi: 10.1016/j.hrthm.2011.06.023
- Saluveer O, Bastani H, Verouhis D, Källner G, Jensen- Urstad M. Transseptal access through an atrial septal defect closure device resulting in open heart surgery. JACC Case Rep. 2022;4(11):685-687. doi: 10.1016/j.jaccas.2022.04.006
- Li X, Wissner E, Kamioka M, et al. Safety and feasibility of transseptal puncture for atrial fibrillation ablation in patients with atrial septal defect closure devices. Heart Rhythm. 2014;11(2):330-335. doi: 10.1016/j.hrthm.2013.11.011
- Tzeis S, Gerstenfeld EP, Kalman J, et al. 2024 European Heart Rhythm Association/Heart Rhythm Society/Asia Pacific Heart Rhythm Society/Latin American Heart Rhythm Society expert consensus statement on catheter and surgical ablation of atrial fibrillation. Europace. 2024;26(4):euae043. doi: 10.1093/europace/euae043
- Lee T, Tsai IC, Fu YC, et al. MDCT evaluation after closure of atrial septal defect with an amplatzer septal occluder. AJR Am J Roentgenol. 2007;188(5):W431-W439. doi: 10.2214/AJR.06.0709
- Himelfarb JD, Shulman H, Olesovsky CJ, et al. Atrial fibrillation following transcatheter atrial septal defect closure: A systematic review and meta-analysis. Heart. 2022;108(15):1216-1224. doi: 10.1136/heartjnl-2021-319794
- Prolic Kalinsek T, Rauber M, Podlogar V, et al. Feasibility, efficacy, and safety of intracardiac echocardiography guided transseptal puncture: A single-center retrospective study. Ep Europace. 2023;25(Supplement_1):euad122.768. doi: 10.1093/europace/euad122.768
- Guo Q, Sang C, Bai R, et al. Transseptal puncture in patients with septal occluder devices during catheter ablation of atrial fibrillation. EuroIntervention. 2022;17(13):1112-1119. doi: 10.4244/EIJ-D-21-00340
- Sang CH, Dong JZ, Long DY, et al. Transseptal puncture and catheter ablation of atrial fibrillation in patients with atrial septal occluder: Initial experience of a single centre. Europace. 2018;20(9):1468-1474. doi: 10.1093/europace/eux282
- Garg J, Shah K, Turagam MK, Janagam P, Natale A, Lakkireddy D. Safety and efficacy of catheter ablation for atrial fibrillation in patients with percutaneous atrial septal closure device: Electrophysiology Collaborative Consortium for Meta-analysis-ELECTRAM investigators. J Cardiovasc Electrophysiol. 2020;31(9):2328-2334. doi: 10.1111/jce.14616
- Sabiniewicz R, Królak T, Wozniak L, Budrejko S, Raczak G. Transesophageal echocardiography guided transseptal puncture for atrial fibrillation ablation in a patient with a 30 mm atrial septal closure device. Postepy Kardiol Interwencyjnej. 2016;12(3):285-286. doi: 10.5114/aic.2016.61658
- Hu J, Ding L, Gunawan E, Lai H, Yao Y. Successful treatment of atrial flutter post-radiofrequency ablation for atrial fibrillation following atrial septal defect occlusion: A case report of pulsed field ablation. Eur Heart J Case Rep. 2024;8:ytae558. doi: 10.1093/ehjcr/ytae558