Woven Endobridge embolization: Indications and innovation
The treatment of intracranial aneurysms has seen incredible advancements over the last few decades. Long-term occlusion of wide-neck bifurcation aneurysms remains technically challenging. The Woven Endobridge (WEB) embolization device is innovative in its construction and uses. The design of the device has evolved over the last decade. Pre-clinical and clinical trials are ongoing and continue to inform the development of intrasaccular flow-diverting devices. The WEB device is currently approved by the U.S. Food and Drug Administration (FDA) for treating wide-neck aneurysms. The safety and efficacy of the WEB device have yielded promising clinical results that may have additional indications. This review aims to discuss the development of the WEB device and the current state of the WEB device in the treatment of wide-neck aneurysms. We also summarize ongoing clinical studies and potential innovative uses.
- Cerebral Aneurysm Secondary Cerebral Aneurysm. Available from: https://www.aans.org/en/patients/neurosurgical-conditions-and-treatments/cerebral-aneurysm [Last accessed on 2023 Feb 27].
- Pierot L, Moret J, Barreau X, et al., 2018, Safety and efficacy of aneurysm treatment with WEB in the cumulative population of three prospective, multicenter series. J Neurointerv Surg, 10: 553–559. https://doi.org/10.1136/neurintsurg-2017-013448
- Moret J, Cognard C, Weill A, et al., 1997, The “Remodelling Technique” in the treatment of wide neck intracranial aneurysms. Angiographic results and clinical follow-up in 56 cases. Interv Neuroradiol, 3: 21–35. https://doi.org/10.1177/159101999700300103
- Shapiro M, Babb J, Becske T, et al., 2008, Safety and efficacy of adjunctive balloon remodeling during endovascular treatment of intracranial aneurysms: A literature review. AJNR Am J Neuroradiol, 29: 1777–1781. https://doi.org/10.3174/ajnr.A1216
- Sluzewski M, van Rooij WJ, Beute GN, et al., 2006, Balloon-assisted coil embolization of intracranial aneurysms: Incidence, complications, and angiography results. J Neurosurg, 105: 396–399. https://doi.org/10.3171/jns.2006.105.3.396
- Fargen KM, Hoh BL, Welch BG, et al., 2012, Long-term results of enterprise stent-assisted coiling of cerebral aneurysms. Neurosurgery, 71: 239–244; discussion 244. https://doi.org/10.1227/neu.0b013e3182571953
- Chow MM, Woo HH, Masaryk TJ, et al., 2004, A novel endovascular treatment of a wide-necked basilar apex aneurysm by using a Y-configuration, double-stent technique. AJNR Am J Neuroradiol, 25: 509–512.
- Horowitz M, Levy E, Sauvageau E, et al., 2006, Intra/extra-aneurysmal stent placement for management of complex and wide-necked-bifurcation aneurysms: Eight cases using the waffle cone technique. Neurosurgery, 58: ONS–258–262; discussion ONS–262. https://doi.org/10.1227/01.neu.0000204713.24945.d2
- Gresele P, 2013, Antiplatelet agents in clinical practice and their haemorrhagic risk. Blood Transfus, 11: 349–356. https://doi.org/10.2450/2013.0248-12
- Cho SH, Jo WI, Jo YE, et al., 2017, Bench-top comparison of physical properties of 4 commercially-available self-expanding intracranial stents. Neurointervention, 12: 31–39. https://doi.org/10.5469/neuroint.2017.12.1.31
- Nakayama Y, Satow T, Funayama M, et al., 2016, Construction of 3 animal experimental models in the development of honeycomb microporous covered stents for the treatment of large wide-necked cerebral aneurysms. J Artif Organs, 19: 179–187. https://doi.org/10.1007/s10047-015-0879-0
- Klisch J, Sychra V, Strasilla C, et al., 2011, The Woven EndoBridge cerebral aneurysm embolization device (WEB II): Initial clinical experience. Neuroradiology, 53: 599–607. https://doi.org/10.1007/s00234-011-0891-x
- Goyal N, Hoit D, DiNitto J, et al., 2020, How to WEB: A practical review of methodology for the use of the Woven EndoBridge. J Neurointerv Surg, 12: 512–520 https://doi.org/10.1136/neurintsurg-2019-015506
- Ding YH, Lewis DA, Kadirvel R, et al., 2011, The Woven EndoBridge: A new aneurysm occlusion device. AJNR Am J Neuroradiol, 32: 607–611. https://doi.org/10.3174/ajnr.A2399
- Goertz L, Liebig T, Siebert E, et al., 2019, Extending the indication of Woven EndoBridge (WEB) embolization to internal carotid artery aneurysms: A multicenter safety and feasibility study. World Neurosurg, 126: e965–e974. https://doi.org/10.1016/j.wneu.2019.02.198
- Rouchaud A, Brinjikji W, Ding YH, et al., 2016, Evaluation of the angiographic grading scale in aneurysms treated with the WEB device in 80 rabbits: Correlation with histologic evaluation. AJNR Am J Neuroradiol, 37: 324–329. https://doi.org/10.3174/ajnr.A4527
- Pierot L, Moret J, Turjman F, et al., 2016, WEB treatment of intracranial aneurysms: Clinical and anatomic results in the french observatory. AJNR Am J Neuroradiol, 37: 655–659. https://doi.org/10.3174/ajnr.a4578
- Pierot L, Costalat V, Moret J, et al., 2016, Safety and efficacy of aneurysm treatment with WEB: Results of the WEBCAST study. J Neurosurg, 124: 1250–1256. https://doi.org/10.3171/2015.2.jns142634
- Pierot L, Spelle L, Molyneux A, et al., 2016, Clinical and anatomical follow-up in patients with aneurysms treated with the WEB device: 1-year follow-up report in the cumulated population of 2 prospective, multicenter series (WEBCAST and French observatory). Neurosurgery, 78: 133–141 https://doi.org/10.1227/neu.0000000000001106
- Pierot L, Gubucz I, Buhk JH, et al., 2017, Safety and efficacy of aneurysm treatment with the WEB: Results of the WEBCAST 2 study. AJNR Am J Neuroradiol, 38: 1151–1155. https://doi.org/10.3174/ajnr.a5178
- Pierot L, Szikora I, Barreau X, et al., 2021, Aneurysm treatment with WEB in the cumulative population of two prospective, multicenter series: 3-year follow-up. J Neurointerv Surg, 13: 363–368. https://doi.org/10.1136/neurintsurg-2020-016151
- Pierot L, Szikora I, Barreau X, et al., 2022, Aneurysm treatment with the Woven EndoBridge (WEB) device in the combined population of two prospective, multicenter series: 5-year follow-up. J Neurointerv Surg, 15: 552–557. https://doi.org/10.1136/neurintsurg-2021-018414
- Fiorella D, Molyneux A, Coon A, et al., 2017, Demographic, procedural and 30-day safety results from the WEB Intra-saccular Therapy Study (WEB-IT). J Neurointerv Surg, 9: 1191–1196. https://doi.org/10.1136/neurintsurg-2016-012841
- Arthur AS, Molyneux A, Coon AL, et al., 2019, The safety and effectiveness of the Woven EndoBridge (WEB) system for the treatment of wide-necked bifurcation aneurysms: Final 12-month results of the pivotal WEB Intrasaccular Therapy (WEB-IT) Study. J Neurointerv Surg, 11: 924–930. https://doi.org/10.1136/neurintsurg-2019-014815
- Cagnazzo F, Marnat G, Ferreira I, et al., 2021, Comparison of Woven EndoBridge device sizing with conventional measurements and virtual simulation using the Sim&Size software: A multicenter experience. J Neurointerv Surg, 13: 924–929. https://doi.org/10.1136/neurintsurg-2020-017060
- Spelle L, Herbreteau D, Caroff J, et al., 2022, CLinical Assessment of WEB device in Ruptured aneurYSms (CLARYS): 12-month angiographic results of a multicenter study. J Neurointerv Surg, Published Online First: 1–6. https://doi.org/10.1136/neurintsurg-2022-018749
- Chalouhi N, Hoh BL, Hasan D, 2013, Review of cerebral aneurysm formation, growth, and rupture. Stroke, 44: 3613–3622. https://doi.org/10.1161/strokeaha.113.002390
- Linzey JR, Griauzde J, Guan Z, et al., 2017, Stent-assisted coiling of cerebrovascular aneurysms: Experience at a large tertiary care center with a focus on predictors of recurrence. J Neurointerv Surg, 9: 1081–1085. https://doi.org/10.1136/neurintsurg-2016-012704
- Ries T, Siemonsen S, Thomalla G, et al., 2007, Long-term follow-up of cerebral aneurysms after endovascular therapy prediction and outcome of retreatment. AJNR Am J Neuroradiol, 28: 1755–1761. https://doi.org/10.3174/ajnr.A0649
- Kabbasch C, Goertz L, Siebert E, et al., 2019, WEB embolization versus stent-assisted coiling: Comparison of complication rates and angiographic outcomes. J Neurointerv Surg, 11: 812–816. https://doi.org/10.1136/neurintsurg-2018-014555
- Mascitelli JR, Moyle H, Oermann EK, et al., 2015, An update to the Raymond-Roy Occlusion Classification of intracranial aneurysms treated with coil embolization. J Neurointerv Surg, 7: 496–502. https://doi.org/10.1136/neurintsurg-2014-011258
- Greve T, Sukopp M, Wostrack M, et al., 2021, Initial Raymond-Roy Occlusion classification but not packing density defines risk for recurrence after aneurysm coiling. Clin Neuroradiol, 31: 391–399. https://doi.org/10.1007/s00062-020-00926-x
- Stapleton CJ, Torok CM, Rabinov JD, et al., 2016, Validation of the Modified Raymond-Roy classification for intracranial aneurysms treated with coil embolization. J Neurointerv Surg, 8: 927–933. https://doi.org/10.1136/neurintsurg-2015-012035
- Darflinger R, Thompson LA, Zhang Z, et al., 2016, Recurrence, retreatment, and rebleed rates of coiled aneurysms with respect to the Raymond-Roy scale: A meta-analysis. J Neurointerv Surg, 8: 507–511. https://doi.org/10.1136/neurintsurg-2015-011668
- Peterson C, Cord BJ, 2021, Recurrent and residual aneurysms after Woven EndoBridge (WEB) therapy: What’s next? Cureus, 13: e14404. https://doi.org/10.7759/cureus.14404
- Zhang SM, Liu LX, Ren PW, et al., 2020, Effectiveness, safety and risk factors of Woven EndoBridge device in the treatment of wide-neck intracranial aneurysms: Systematic review and meta-analysis. World Neurosurg, 136: e1–e23. https://doi.org/10.1016/j.wneu.2019.08.023
- Srinivasan VM, Dmytriw AA, Regenhardt RW, et al., 2022, Retreatment of residual and recurrent aneurysms after embolization with the woven EndoBridge device: Multicenter case series. Neurosurgery, 90: 569–580. https://doi.org/10.1227/neu.0000000000001883
- Pierot L, 2021, Ten years of clinical evaluation of the woven EndoBridge: A safe and effective treatment for wide-neck bifurcation aneurysms. Neurointervention, 16: 211–221. https://doi.org/10.5469/neuroint.2021.00395
- McPheeters MJ, Vakharia K, Munich SA, et al., 2019, Wide-necked cerebral artery aneurysms: Where do we stand? Endovascular Today, 18: 70–79.
- Wallner AK, Broussalis E, Hauser T, et al., 2012, Coiling after treatment with the woven EndoBridge cerebral aneurysm embolization device. A case report. Interv Neuroradiol, 18: 208–212. https://doi.org/10.1177/159101991201800214
- Turjman F, Massoud TF, Ji C, et al., 1994, Combined stent implantation and endosaccular coil placement for treatment of experimental wide-necked aneurysms: A feasibility study in swine. AJNR Am J Neuroradiol, 15: 1087–1090.
- Modi J, Eesa M, Menon BK, et al., 2011, Balloon-assisted rapid intermittent sequential coiling (BRISC) technique for the treatment of complex wide-necked intracranial aneurysms. Interv Neuroradiol, 17: 64–69. https://doi.org/10.1177/159101991101700110
- Secondary. Available from: https://radiopaedia.org/articles/ raymondroy-occlusion-classification-of-intracranial-aneurysms-1?lang=us [Last accessed on 2023 Feb 27].
- Pierot L, Biondi A, Narata AP, et al., 2017, Should indications for WEB aneurysm treatment be enlarged? Report of a series of 20 patients with aneurysms in “atypical” locations for WEB treatment. J Neuroradiol, 44: 203–209.https://doi.org/10.1016/j.neurad.2016.12.011
- Zimmer S, Maus V, Maurer C, et al., 2021, Widening the indications for intrasaccular flow disruption: WEB 17 in the treatment of aneurysm locations different from those in the good clinical practice trials. AJNR Am J Neuroradiol, 42: 524–529. https://doi.org/10.3174/ajnr.A6946
- Pierot L, Cognard C, Anxionnat R, et al., 2012, Endovascular treatment of ruptured intracranial aneurysms: Factors affecting midterm quality anatomic results: Analysis in a prospective, multicenter series of patients (CLARITY). AJNR Am J Neuroradiol, 33: 1475–1480. https://doi.org/10.3174/ajnr.A3003
- Fargen KM, Velat GJ, Lawson MF, et al., 2013, The stent anchor technique for distal access through a large or giant aneurysm. J Neurointerv Surg, 5: e24. https://doi.org/10.1136/neurintsurg-2012-010276
- Hope JK, Byrne JV, Molyneux AJ, 1999, Factors influencing successful angiographic occlusion of aneurysms treated by coil embolization. AJNR Am J Neuroradiol, 20: 391–399.
- Turjman F, Massoud TF, Sayre J, et al., 1998, Predictors of aneurysmal occlusion in the period immediately after endovascular treatment with detachable coils: A multivariate analysis. AJNR Am J Neuroradiol, 19: 1645–1651.
- Mine B, Bonnet T, Vazquez-Suarez JC, et al., 2018, Comparison of stents used for endovascular treatment of intracranial aneurysms. Expert Rev Med Devices 15: 793–805. https://doi.org/10.1080/17434440.2018.1538779
- Morsy A, Mahmoud M, Abokresha AE, et al., 2022, Intracranial wide neck aneurysms: Clinical and angiographic outcomes of endovascular management. Egypt J Neurol Psychiatr Neurosurg, 58: 108. https://doi.org/10.1186/s41983-022-00546-x
- Kadirvel R, Ding YH, Dai D, et al., 2014, Cellular mechanisms of aneurysm occlusion after treatment with a flow diverter. Radiology, 270: 394–399. https://doi.org/10.1148/radiol.13130796
- Spiotta AM, Derdeyn CP, Tateshima S, et al., 2017, Results of the ANSWER trial using the PulseRider for the treatment of broad-necked, bifurcation aneurysms. Neurosurgery, 81: 56–65. https://doi.org/10.1093/neuros/nyx085
- Ricci DR, de Vries J, Blanc R, 2017, Role of preliminary registry data in development of a clinical trial for an innovative device: A small but integral piece of a health policy initiative. J Mark Access Health Policy, 5: 1283106. https://doi.org/10.1080/20016689.2017.1283106
- Fischer S, Weber A, Carolus A, et al., 2017, Coiling of wide-necked carotid artery aneurysms assisted by a temporary bridging device (Comaneci): Preliminary experience. J Neurointerv Surg, 9: 1039–1097. https://doi.org/10.1136/neurintsurg-2016-012664
- Jia ZY, Shi HB, Miyachi S, et al., 2018, Development of new endovascular devices for aneurysm treatment. J Stroke, 20: 46–56. https://doi.org/10.5853/jos.2017.02229
- Sirakov S, Panayotova A, Sirakov A, et al., 2019, Treatment of recurrent wide neck bifurcation aneurysm with the barrel vascular reconstruction device. Front Neurol, 10, 1159. https://doi.org/10.3389/fneur.2019.01159
- Armoiry X, Turjman F, Hartmann DJ, et al., 2016, Endovascular treatment of intracranial aneurysms with the WEB device: A systematic review of clinical outcomes. AJNR Am J Neuroradiol, 37: 868–872. https://doi.org/10.3174/ajnr.A4611
- Fiorella D, Arthur AS, Chiacchierini R, et al., 2017, How safe and effective are existing treatments for wide-necked bifurcation aneurysms? Literature-based objective performance criteria for safety and effectiveness. J Neurointerv Surg, 9: 1197–1201. https://doi.org/10.1136/neurintsurg-2017-013223
- Ansari S, Zevallos CB, Farooqui M, et al., 2021, Optimal Woven EndoBridge (WEB) device size selection using automated volumetric software. Brain Sci, 11: 901. https://doi.org/10.3390/brainsci11070901
- Rai AT, Turner RC, Brotman RG, et al., 2021, Comparison of operating room variables, radiation exposure and implant costs for WEB versus stent assisted coiling for treatment of wide neck bifurcation aneurysms. Interv Neuroradiol, 27: 465–472. https://doi.org/10.1177/1591019920965392
- Adeeb N, Dibas M, Diestro JD, et al., 2022, Multicenter study for the treatment of sidewall versus bifurcation intracranial aneurysms with use of woven EndoBridge (WEB). Radiology, 304: 372–382. https://doi.org/10.1148/radiol.212006
- Aguiar G, Caroff J, Mihalea C, et al., 2022, WEB device for treatment of posterior communicating artery aneurysms. J Neurointerv Surg, 14: 362–365. https://doi.org/10.1136/neurintsurg-2021-017405
- Virtual Simulation for Woven EndoBridge Device Sizing . Available from: https://clinicaltrials.gov/show/nct04621552 [Last accessed on 2023 Feb 27].
- WEB French Observatory of the WEB Aneurysm Embolization System. Available from: https://clinicaltrials.gov/show/nct01975233 [Last accessed on 2023 Feb 27].
- WEB Clinical Assessment of IntraSaccular Aneurysm Therapy. Available from: https://clinicaltrials.gov/show/nct01778322 [Last accessed on 2023 Feb 27].
- CLARYS: CLinical Assessment of WEB® Device in Ruptured aneurYSms. Available from: https://clinicaltrials.gov/show/nct02687607 [Last accessed on 2023 Feb 27].
- CLinical EValuation of WEB 0.017 Device in Intracranial AneuRysms. Available from: https://clinicaltrials.gov/show/nct03844334 [Last accessed on 2023 Feb 27].
- The WEB-IT Clinical Study. Available from: https:// clinicaltrials.gov/show/nct02191618 [Last accessed on 2023 Feb 27].
- The RISE Trial: A Randomized Trial on Intra-saccular Endobridge Devices. Available from: https://clinicaltrials.gov/show/nct03936647 [Last accessed on 2023 Feb 27].
- Mid-term Data Collection of the Treatment of Intracranial Aneurysms with the WEB™ Aneurysm Embolization System. Available from: https://clinicaltrials.gov/show/nct03379714 [Last accessed on 2023 Feb 27].
- Post Approval Study-evaluate the Long-term Safety and Effectiveness of the WEB Device. Available from: https:// clinicaltrials.gov/show/nct04839705 [Last accessed on 2023 Feb 27].
- The WEB®-IT China Clinical Study. Available from: https://clinicaltrials.gov/show/nct03207087 [Last accessed on 2023 Feb 27].
- Givens JL, Tjia J, 2002, Depressed medical students’ use of mental health services and barriers to use. Acad Med, 77: 918–921. https://doi.org/10.1097/00001888-200209000-00024