Retrospective comparative study of CT-guided needle localization versus medical glue localization for preoperative management of pulmonary nodules

Background: Video-assisted thoracoscopic surgery (VATS) is the preferred treatment for pulmonary nodules, making preoperative localization crucial. Aim: This study compared the effectiveness and complications of two computed tomography (CT)-guided localization methods for pulmonary nodules: localization needle and medical glue. Methods: This retrospective study included 86 patients with pulmonary nodules undergoing preoperative localization at the First Affiliated Hospital of Guangxi Medical University (July 2023 – April 2024). The patients were divided into two groups: the localization needle group (n=64) and the medical glue group (n=22). Clinical data, including baseline characteristics, localization-related data, complications, and surgical outcomes, were collected and analyzed, and subgroup analyses were done to identify risk factors for pneumothorax and pulmonary hemorrhage. Results: Both methods achieved a 100% localization success rate, with all nodules successfully resected. The needle group had longer localization time (17.19 vs. 15.36 min, p<0.05) and higher pneumothorax incidence (23.4% vs. 4.5%, p<0.05). The needle group also had a lower cough incidence (1.6% vs. 22.7%, p<0.05) but higher pain scores (2.89 vs. 2.36, p<0.05). No significant differences were observed in intrapulmonary hemorrhage, operative time, surgical approach, or postoperative pathology (p>0.05) between the two groups. However, subgroup analysis revealed significant differences in puncture times, localization methods, nodule size, lung history, and puncture depth related to pneumothorax and hemorrhage (p<0.05). Conclusion: Both CT-guided localization methods are safe and effective for VATS. The number of punctures is a key risk factor for complications such as pneumothorax and intrapulmonary hemorrhage, emphasizing the importance of careful planning and technique during localization. Relevance for patients: Identifying the most effective localization methods for pulmonary nodules ensures a higher success rate in surgeries, with fewer complications, ultimately leading to better patient outcomes and faster recovery. Proper preoperative localization helps reduce the risk of adverse events like pneumothorax, ensuring safer procedures and improved overall care for patients.

- Siegel RL, Miller KD, Wagle NS, Jemal A. Cancer Statistics, 2023. CA Cancer J Clin 2023;73:17-48. doi: 10.3322/caac.21763
- Han B, Zheng R, Zeng H, Wang S, Sun K, Chen R, et al. Cancer Incidence and Mortality in China, 2022. J Natl Cancer Cent 2024;4:47-53. doi: 10.1016/j.jncc.2024.01.006
- Lancaster HL, Heuvelmans MA, Oudkerk M. Low-dose Computed Tomography Lung Cancer Screening: Clinical Evidence and Implementation Research. J Intern Med 2022;292:68-80. doi: 10.1111/joim.13480
- Mazzone PJ, Lam L. Evaluating the Patient with A Pulmonary Nodule: A Review. JAMA 2022;327:264-73. doi: 10.1001/jama.2021.24287
- Feray S, Lubach J, Joshi GP, Bonnet F, Van De Velde M. PROSPECT Guidelines for Video-assisted Thoracoscopic Surgery: A Systematic Review and Procedure-specific Postoperative Pain Management Recommendations. Anaesthesia 2022;77:311-25. doi: 10.1111/anae.15609
- Keating J, Singhal S. Novel Methods of Intraoperative Localization and Margin Assessment of Pulmonary Nodules. Semin Thorac Cardiovasc Surg 2016;28:127-36. doi: 10.1053/j.semtcvs.2016.01.006
- Tang L, Zhang Y, Wang Y. Intraoperative Identification of Pulmonary Nodules During Minimally Invasive Thoracic Surgery: A Narrative Review. Quant Imaging Med Surg 2022;12:5271-87. doi: 10.21037/qims-22-309
- Li CD, Huang ZG, Sun HL, Wang LT, Wang YL, Gao BX, et al. Marking Ground Glass Nodules with Pulmonary Nodules Localization Needle Prior to Video-assisted Thoracoscopic Surgery. Eur Radiol 2022;32:4699-706. doi: 10.1007/s00330-022-08597-7
- Wang Y, Chen E. Advances in the Localization of Pulmonary Nodules: A Comprehensive Review. J Cardiothorac Surg 2024;19:396. doi: 10.1186/s13019-024-02911-8
- Wang L, Sun D, Gao M, Li C. Computed Tomography-guided Localization of Pulmonary Nodules Prior to Thoracoscopic Surgery. Thorac Cancer 2023;14:119-26. doi: 10.1111/1759-7714.14754
- McDaniel JD, Racadio JM, Patel MN, Johnson ND, Kukreja K. CT-guided Localization of Pulmonary Nodules in Children Prior to Video-Assisted Thoracoscopic Surgical Resection Utilizing A Combination of two Previously Described Techniques. Pediatr Radiol 2018;48:626-31. doi: 10.1007/s00247-018-4069-0
- Ye W, Dong C, Lin C, Wu Q, Li J, Zhou Z, et al. Medical Adhesive VS Hookwire for Computed Tomography-guided Preoperative Localization and Risk Factors of Major Complications. Br J Radiol 2021;94:20201208. doi: 10.1259/bjr.20201208
- Rothman A, Lim S, Hasegawa D, Steiger D, Patel R, Lee YI. Abnormal Pulmonary Function Testing as an Independent Risk Factor for Procedural Complications During Transthoracic Needle Biopsies. J Bronchology Interv Pulmonol 2022;29:213-9. doi: 10.1097/LBR.0000000000000819
- Xin N, Wu X, Chen Z, Wei R, Saito Y, Lachkar S, et al. A New Preoperative Localization of Pulmonary Nodules Guided by Mixed Reality: A Pilot Study of an Animal Model. Transl Lung Cancer Res 2023;12:150-7. doi: 10.21037/tlcr-22-884
- Anayama T, Yamamoto M, Hirohashi K, Miyazaki R, OkadaH, Doi A, et al. The Accuracy of Cone-beam Computed Tomography and Augmented Fluoroscopy-guided Bronchoscopic Marking of Multiple Small-sized Pulmonary Nodules in a Hybrid Operating Room: A Retrospective Cohort Study. Quant Imaging Med Surg 2021;11:725-36. doi: 10.21037/qims-20-781
- Rho J, Lee JW, Quan YH, Choi BH, Shin BK, Han KN, et al. Fluorescent and Iodized Emulsion for Preoperative Localization of Pulmonary Nodules. Ann Surg 2021;273:989-96. doi: 10.1097/SLA.0000000000003300
- Zhang H, Zhang X, Li Y, Huang Z, Liu H, Chen X. The Efficacy and Safety of CT-guided Localization of Pulmonary Nodules by Medical Adhesives Containing Methylene Blue Before Surgery. Heliyon 2024;10:e31404. doi: 10.1016/j.heliyon.2024.e31404
- Xu J, Si T, Zheng M, Guan J, Li Z, Xu Z. CT Guided Autologous Blood Localization of Pulmonary Ground Glass Nodules for Video Assisted Thoracoscopic Surgery Compared to Micro- Coil Localization. J Cardiothorac Surg 2022;17:183. doi: 10.1186/s13019-022-01934-3
- Kong J, Guo J, Zhang H, Li Y, Wang G, Zhang Y. CT-Guided Localization Techniques of Small Pulmonary Nodules: A Prospective Non-randomized Controlled Study on Pulmonary Nodule Localization Needle and Methylene Blue Staining with Surgical Glue. J Thorac Dis 2020;12:6826-35. doi: 10.21037/jtd-20-3147
- Kleedehn M, Kim DH, Lee FT, Lubner MG, Robbins JB, Ziemlewicz TJ, et al. Preoperative Pulmonary Nodule Localization: A Comparison of Methylene Blue and Hookwire Techniques. AJR Am J Roentgenol 2016;207:1334-9. doi: 10.2214/AJR.16.16272
- Wang Z, Li B, Hu Z, Zhao Q, Zhang X, Zhao H, et al. Comparison of Different Localization Needles and Postures in Localization of Pulmonary Nodules. J Cardiothorac Surg 2024;19:668. doi: 10.1186/s13019-024-03144-5
- Yoshida J, Nagai K, Nishimura M, Takahashi K. Computed Tomography-fluoroscopy Guided Injection of Cyanoacrylate to Mark A Pulmonary Nodule for Thoracoscopic Resection. Jpn J Thorac Cardiovasc Surg 1999;47:210-3. doi: 10.1007/BF03217996
- Mazur M, Zakrzewski W, Szymonowicz M, Rybak Z. Medical Adhesives and Their Role in Laparoscopic Surgery-A Review of Literature. Materials (Basel) 2022;15:5215. doi: 10.3390/ma15155215
- Zhang H, Li Y, Chen X, He Z. Comparison of Hook-wire and Medical Glue for CT-guided Preoperative Localization of Pulmonary Nodules. Front Oncol 2022;12:922573. doi: 10.3389/fonc.2022.922573
- Yu S, Li W, Liu X, Chen X, He X, Duan X, et al. Application Value of CT-guided Localization Using A Coil in Combination with Medical Adhesive in Sublobar Resection. Clin Transl Oncol 2023;25:2931-7. doi: 10.1007/s12094-023-03156-y
- Du A, Hannan L, Muruganandan S. A Narrative Review on Pain Control Interventions for Non-Surgical Pleural Procedures. Respir Med 2023;207:107119. doi: 10.1016/j.rmed.2023.107119
- Tao G, Jingying Y, Tan G, Xiaotao D, Min C. A Novel CT-guided Technique Using Medical Adhesive for Localization of Small Pulmonary Ground-glass Nodules and Mixed Ground-Glass Nodules (≤20 mm) Before Video-assisted Thoracoscopic Surgery. Diagn Interv Radiol 2018;24:209-12. doi: 10.5152/dir.2018.17315
- Pezeshkian F, McAllister M, Singh A, Jaklitsch MT, Gill RR, Bueno R, et al. Image-guided Video-assisted Thoracoscopic Surgery (iVATS): A Single Center Experience and Review. J Thorac Dis 2023;15:7035-41. doi: 10.21037/jtd-23-1461
- Huang Y, Zhao Z, Wang T, Yang J, Lu Z, Wang B, et al. A Comparison between Prethoracoscopy Localization of Small Pulmonary Nodules by Means of Medical Adhesive versus Hookwire. J Vasc Interv Radiol 2018;29:1547-52. doi: 10.1016/j.jvir.2018.05.013
- Liu Y, Hou Z, Wu K, Zhu Y, Wang H, Han Y. α-Cyanoacrylate Rapid Medical Adhesive (Medical EC Glue) Localization of Pulmonary Nodules Guided by Computed Tomography before Thoracoscopic Surgery. Curr Med Imaging 2023;19:382-8. doi: 10.2174/1573405618666220920113257
- Menniti M, Laganà F, Oliva G, Bianco M, Fiorillo AS, Pullano SA. Development of Non-invasive Ventilator for Homecare and Patient Monitoring System. Electronics 2024;13:790. doi: 10.3390/electronics13040790
- Ferrera MC, Labaki WW, Han MK. Advances in Chronic Obstructive Pulmonary Disease. Annu Rev Med 2021;72:119-34. doi: 10.1146/annurev-med-080919-112707
- Janssen R, Piscaer I, Franssen FM, Wouters EF. Emphysema: Looking Beyond Alpha-1 Antitrypsin Deficiency. Expert Rev Respir Med 2019;13:381-97. doi: 10.1080/17476348.2019.1580575
- Yao F, Wang J, Yao J, Xu L, Wang J, Gao L. Reevaluation of the Efficacy of Preoperative Computed Tomography-guided Hook Wire Localization: A Retrospective Analysis. Int J Surg 2018;51:24-30. doi: 10.1016/j.ijsu.2018.01.014
- Chiu JH, Chang YY, Weng CY, Lee YC, Yeh YC, Chen CK. Risk Factors for Pneumothorax and Pulmonary Hemorrhage Following Computed Tomography-guided Transthoracic Core-needle Biopsy of Subpleural Lung Lesions. J Chin Med Assoc 2022;85:500-6. doi: 10.1097/JCMA.0000000000000705